OneTouch Verio Flex® – Preparing for a Blood Glucose Test - Notes and Cautions
OneTouch-Verio-Flex-Preparing-for-a-Blood-Glucose-Test-Notes-and-Cautions
Important notes and cautions to understand before blood glucose testing with the OneTouch VerioFlex® meter.
Product Guide
USA
OneTouch Verio Flex® meter
English
5.0
Article Details

Preparing For A Blood Glucose Test:
 

  • Have these things ready when you test:
    • OneTouch Verio Flex® Meter
    • OneTouch Verio® Test Strips
    • Lancing device
    • Sterile lancets
 
  • Notes:
    • Use only OneTouch Verio® Test Strips.
    • Unlike some blood glucose meters, no separate step to code your OneTouch Verio Flex® System is required.
    • Testing must be done within operating temperature range (50-104°F).
    • Make sure your meter and test strips are about the same temperature before you test.
    • Keep test strips in a cool, dry place between 41°F and 86°F.
    • Do Not test if there is condensation (water build-up) on your meter. Move your meter and test strips to a cool, dry spot and wait for the meter surface to dry before testing.
    • Do Not open the test strip vial until you are ready to remove a test strip and perform a test. Use the test strip immediately after removing it from the vial.
    • Tightly close the cap on the vial immediately after use to avoid contamination and damage.
    • Store unused test strips only in their original vial.
    • Do Not return the used test strip to the vial after performing a test.
    • Do Not re-use a test strip that had blood, control solution, or any contaminants applied to it. Test strips are for single use only.
    • With clean, dry hands, you may touch the test strip anywhere on its surface. Do Not bend, cut or modify the test strip in any way.
    • When you first open a vial of test strips, record the discard date on the label. Refer to the test strip insert or vial label for instructions on determining the discard date.
    • Comparing your blood glucose test results taken with this meter to your results taken from a different meter is not recommended. Results may differ between meters and are not a useful measure of whether your meter is working properly.
 
 
  • CAUTION:
    • The OneTouch Verio Flex® Blood Glucose Monitoring System should not be used within 24 hours of receiving a D-xylose absorption test as it may cause inaccurately high results.
    • Do Not use the OneTouch Verio® Family of Meters when PAM (Pralidoxime) is known or suspected to be in the whole blood sample.
    • Do Not use your test strips if your vial is damaged or left open to air. This could lead to error messages or inaccurate results. Contact OneTouch® Customer Care immediately if the test strip vial is damaged.
    • If you cannot test due to a problem with your testing supplies, contact your healthcare professional. Failure to test could delay treatment decisions and lead to a serious medical condition.
    • The test strip vial contains drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation.
    • Do Not use test strips after the expiration date (printed on the vial) or the discard date, whichever comes first, or your results may be inaccurate.